Automatic Ingestion Monitor: A Novel Wearable Device for Monitoring of Ingestive Behavior

dc.contributor.authorFontana, Juan M.
dc.contributor.authorFarooq, Muhammad
dc.contributor.authorSazonov, Edward
dc.contributor.otherUniversity of Alabama Tuscaloosa
dc.contributor.otherUniversidad Nacional Rio Cuarto
dc.date.accessioned2023-09-28T19:11:30Z
dc.date.available2023-09-28T19:11:30Z
dc.date.issued2014
dc.description.abstractObjective monitoring of food intake and ingestive behavior in a free-living environment remains an open problem that has significant implications in study and treatment of obesity and eating disorders. In this paper, a novel wearable sensor system (automatic ingestion monitor, AIM) is presented for objective monitoring of ingestive behavior in free living. The proposed device integrates three sensor modalities that wirelessly interface to a smartphone: a jaw motion sensor, a hand gesture sensor, and an accelerometer. A novel sensor fusion and pattern recognition method was developed for subject-independent food intake recognition. The device and the methodology were validated with data collected from 12 subjects wearing AIM during the course of 24 h in which both the daily activities and the food intake of the subjects were not restricted in any way. Results showed that the system was able to detect food intake with an average accuracy of 89.8%, which suggests that AIM can potentially be used as an instrument to monitor ingestive behavior in free-living individuals.en_US
dc.format.mediumelectronic
dc.format.mimetypeapplication/pdf
dc.identifier.citationFontana, J. M., Farooq, M., & Sazonov, E. (2014). Automatic Ingestion Monitor: A Novel Wearable Device for Monitoring of Ingestive Behavior. In IEEE Transactions on Biomedical Engineering (Vol. 61, Issue 6, pp. 1772–1779). Institute of Electrical and Electronics Engineers (IEEE). https://doi.org/10.1109/tbme.2014.2306773
dc.identifier.doi10.1109/TBME.2014.2306773
dc.identifier.orcidhttps://orcid.org/0000-0001-5000-0402
dc.identifier.orcidhttps://orcid.org/0000-0001-7792-4234
dc.identifier.orcidhttps://orcid.org/0000-0002-8934-1359
dc.identifier.urihttps://ir.ua.edu/handle/123456789/10995
dc.languageEnglish
dc.language.isoen_US
dc.publisherIEEE
dc.subjectAutomatic ingestion monitor (AIM)
dc.subjectchewing
dc.subjecteating disorders
dc.subjectfood intake (FI) detection
dc.subjectobesity
dc.subjectpattern recognition
dc.subjectwearable sensors
dc.subjectEATING-DISORDERS
dc.subjectPREVALENCE
dc.subjectSENSORS
dc.subjectOBESITY
dc.subjectEngineering, Biomedical
dc.titleAutomatic Ingestion Monitor: A Novel Wearable Device for Monitoring of Ingestive Behavioren_US
dc.typeArticle
dc.typetext

Files

Original bundle
Now showing 1 - 1 of 1
Loading...
Thumbnail Image
Name:
10.1109TBME.2014.2306773.pdf
Size:
375.7 KB
Format:
Adobe Portable Document Format