Matilda: a mass filtered nanocluster source

Show simple item record

dc.contributor Turner, C. Heath
dc.contributor Weaver, Mark Lovell
dc.contributor Mankey, Gary J.
dc.contributor Lane, Alan M.
dc.contributor.advisor Klein, Tonya M.
dc.contributor.author Kwon, GiHan
dc.date.accessioned 2017-02-28T22:21:14Z
dc.date.available 2017-02-28T22:21:14Z
dc.date.issued 2009
dc.identifier.other u0015_0000001_0000101
dc.identifier.other Kwon_alatus_0004D_10056
dc.identifier.uri https://ir.ua.edu/handle/123456789/608
dc.description Electronic Thesis or Dissertation
dc.description.abstract Cluster science provides a good model system for the study of the size dependence of electronic properties, chemical reactivity, as well as magnetic properties of materials. One of the main interests in cluster science is the nanoscale understanding of chemical reactions and selectivity in catalysis. Therefore, a new cluster system was constructed to study catalysts for applications in renewable energy. Matilda, a nanocluster source, consists of a cluster source and a Retarding Field Analyzer (RFA). A moveable AJA A310 Series 1"-diameter magnetron sputtering gun enclosed in a water cooled aggregation tube served as the cluster source. A silver coin was used for the sputtering target. The sputtering pressure in the aggregation tube was controlled, ranging from 0.07 to 1torr, using a mass flow controller. The mean cluster size was found to be a function of relative partial pressure (He/Ar), sputtering power, and aggregation length. The kinetic energy distribution of ionized clusters was measured with the RFA. The maximum ion energy distribution was 2.9 eV/atom at a zero pressure ratio. At high Ar flow rates, the mean cluster size was 20 ~ 80nm, and at a 9.5 partial pressure ratio, the mean cluster size was reduced to 1.6nm. Our results showed that the He gas pressure can be optimized to reduce the cluster size variations. Results from SIMION, which is an electron optics simulation package, supported the basic function of an RFA, a three-element lens and the magnetic sector mass filter. These simulated results agreed with experimental data. For the size selection experiment, the channeltron electron multiplier collected ionized cluster signal at different positions during Ag deposition on a TEM grid for four and half hours. The cluster signal was high at the position for neutral clusters, which was not bent by a magnetic field, and the signal decreased rapidly far away from the neutral cluster region. For cluster separation according to mass to charge ratio in a magnetic sector mass filter, the ion energy of the cluster and its distribution must be precisely controlled by acceleration or deceleration. To verify the size separation, a high resolution microscope was required. Matilda provided narrow particle sized distribution from atomic scale to 4nm in size with different pressure ratio without additional mass filter. It is very economical way to produce relatively narrow particle size distribution.
dc.format.extent 121 p.
dc.format.medium electronic
dc.format.mimetype application/pdf
dc.language English
dc.language.iso en_US
dc.publisher University of Alabama Libraries
dc.relation.ispartof The University of Alabama Electronic Theses and Dissertations
dc.relation.hasversion born digital
dc.rights All rights reserved by the author unless otherwise indicated.
dc.subject.other Engineering, Chemical
dc.subject.other Physics, Optics
dc.title Matilda: a mass filtered nanocluster source
dc.type thesis
dc.type text
etdms.degree.department University of Alabama. Dept. of Chemical and Biological Engineering
etdms.degree.discipline Chemical & Biological Engineering
etdms.degree.grantor The University of Alabama
etdms.degree.level doctoral
etdms.degree.name Ph.D.


Files in this item

This item appears in the following Collection(s)

Show simple item record

Search DSpace


Browse

My Account